Back to Top

Hi, Guest!

  LOKASI :  Kabupaten Sumedang

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • CURENT METER
  • UNIDATA 6526H Starflow Ultrasonic Doppler Logger Instruments

UNIDATA 6526H Starflow Ultrasonic Doppler Logger Instruments

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
24 kali

Harga

CALL
Bagikan
:
CV. Gihon Juma Sentosa Merupakan Distributor Untuk Kebutuhan Instrument Industri, Bahan kimia Merck,Instrument laboratorium pendidikan. Kami Menyediakan Gas Industry , alat laboratorium, Alat Survey dan Bahan Kimia teknis kebutuhan skala besar.

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail UNIDATA 6526H Starflow Ultrasonic Doppler Logger Instruments

CURRENT METER

The Starflow Ultrasonic Doppler Instrument is a compact, easy-to-use system for measuring the velocity and depth of water in drainage channels, large pipes, and in rivers and streams.
It is suitable for use in a wide range of water qualities, from sewerage and waste water to clean streams, potable water, and even sea water. The instrument measures forward and reverse flow conditions and may be programmed to compute Flow Rate and Total Flow in pipes and open channels.

The Model 6526H Starflow combines an ultrasonic transducer assembly (profiled to reduce flow disturbance) with signal processing electronics. It is designed to be placed at (or near) the bottom of a water channel for “upward looking” measurement. A single cable connects the instrument to a 12VDC power source.

Water velocity is measured by the Starflow ultrasonic Doppler principle which relies on suspended particles or small air bubbles in the water to reflect the ultrasonic detector signal. The instrument will not operate in very clean, “de-gassed” water. Water depth is gauged by a hydrostatic pressure sensor, referenced to atmospheric pressure through the vented power and signal cable.

Water temperature is also measured so the instrument can adjust for the change in velocity due to speed of sound. Water temperature can also be logged.
Two version are available, depending on the requirements:

Velocity
Range: 21mm/s to 4500mm/s bi-directional
Accuracy: 2% of measured velocity
Resolution: 1mm/s
Depth: 0 to 5m in two ranges

Resolution
Range: 0m to 2.0m; 0m to 5.0m
Accuracy: Typical ±0.25%

Temperature
Temperature: -17°C to 60°C
Resolution: 0.1°C.

Flow 
Computation: Flow rate, totalised flow
Channel Type: Pipe, open channel, natural stream

Integrated MicroLogger
Storage Memory: 512kB, CMOS RAM
Log Interval: Programmable, 5s to 1 week
Communication: RS-232, 300-38400bps
SDI-12: 1200bps instrument channel.
Control: CMOS output trigger (water sampler)

General
Cable: 15 metres, 9 way vented
Cable Options: User specified up to 100 metres
Power Source: External battery 12V DC
Power Usage:
11.5VDC to 15VDC
65uA standby
200mA active
90mA communications
Operating Temp: 0°C to 60°C water temperature.
Material: PVC body, stainless steel mounting plate
Dimensions: 290mm x 70mm x 25mm
Weight: 2kg with 15m cable

Tampilkan Lebih Banyak