ISOTECH Venus 4951 (Site) Temperature Calibrator

Update Terakhir
:
19 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
10 kali

Harga

CALL
Bagikan
:
CV. Gihon Juma Sentosa Merupakan Distributor Untuk Kebutuhan Instrument Industri, Bahan kimia Merck,Instrument laboratorium pendidikan. Kami Menyediakan Gas Industry , alat laboratorium, Alat Survey dan Bahan Kimia teknis kebutuhan skala besar.

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail ISOTECH Venus 4951 (Site) Temperature Calibrator

CALIBRATOR

The Isotech Venus 4951 temperature calibrator can be used as a dry block or liquid bath. Accessories are available for converting to a stirred liquid bath, surface sensor calibration, to calibrate infrared thermometers and even to use as an ITS-90 Fixed Point System with calibration uncertainties as small as 0.0005°C. With excellent stability and distributed heating / cooling zones for good uniformity these calibrators offer proven thermal performance, are easy to use, and available in three models.

Basic Model
Digital display of set and nominal block temperature
Use with a separate external indicator to compensate for gradients and loading
Calibrator does not need calibrating; only the indicator & sensor need re-calibration
Cal Notepad software
Serial PC interface

Site Model
Digital display of set and nominal block temperature
Single channel indicator for reference probe
Best Practice calibration with established traceability and uncertainty
Re-calibration requires sending whole unit in
Cal Notepad software
Serial PC interface

Advanced Model
Digital display of set and nominal block temperature
Three channel indicator for reference probe and units under test
Advanced features including automatic temperature cycling and logging
Best Practice calibration with established traceability and uncertainty
Re-calibration requires sending whole unit in
I-Cal Easy LOG software & built-in web server
Ethernet & USB host PC interface

Features:
35 x 160mm calibration volume
±0.03°C stability (Basic & Site models)
±0.01°C stability (Advanced model)
Common uniformity specifications
<0.02°C Radial, Liquid Bath mode
<0.026°C Axial, Liquid Bath mode (40mm)
<0.008°C Radial, Dry Block mode (between wells)
<0.040°C Axial, Dry Block mode (40mm)
15min heating time from -30 to 140°C
15min to cool from 140 to 0°C

What's In The Box:
(1) Standard insert
(1) 3 point traceable certificate
(1) Instruction manual