Detail CHAUVIN ARNOUX CA 1886 Thermal Imaging Camera

ALAT PENGUKUR SUHU

The Chauvin Arnous RayCAm C.A 1886 and C.A 1888 high resolution infrared cameras provide thorough thermal analysis with comprehensive parameterization. They incorporate a large TFT screen for easier reading. Temperature sensitivity up to 600 °C and a temperature detection matrix resolution of up to 384 x 288 (C.A 1888). Complete IR-Merge functions (IR image in real image from 0 to 100 %).
 
Field of view: 20° x 15° (CA1886 740-6470) and 24° x 18° (CA1888 740-6474)
Matrix resolution: 160 x 120 (740-6470) and 384 x 288 (740-6474)
IR and real image merge, 0 to 100%
IP 54 leakproofing
Excellent legibility thanks to its multidirectional screen, even in places where access is difficult
Comfortable handling due to its pistol shape
Automatic detection and indication of hottest/coldest point
Parameter settings affecting measurement:
Adjustable emissivity
Adjustment of measurement distance
Parameters for defining relative humidity and ambient temperature
Parameterizable alarms
Isotherm function
Storage capacity of 1,000 radiometric images organized in 250 folders and back-up on mini-SD card (2GB max.)
 
Supplied with
Delivered in a case with 1 battery charger, 2 batteries, a 2GB mini-SD Card, 1 SD card reader, 1 video cable, RayCAm Report software and a measurement report.
 
Specifications
Attribute Value
Temperature Measurement Range -20 → +600 °C
Thermal Sensitivity ≤0.08°C
Field of View H x V 24 x 18°
Best Temperature Measurement Accuracy ±2% + 2 °C
Maximum Temperature Measurement +600 °C
Refresh Rate 50Hz
Minimum Focus Distance 10cm
Detector Resolution 384 x 288pixel
Focus Type Manual
Visual Camera Yes
Minimum Focus 10 cm
Display Size 3.5in
Voice Recorder Yes
Interface Type USB
Image Storage SD Card
Display Resolution 640 x 480pixel
Application Thermography
Field of View 24 x 18°
Model Number C.A 1888
Horizontal Detector Resolution 384pixel
Storage Media SD Card
Vertical Display Resolution 480pixel
Vertical Field of View 18°
Model Number p C.A 1888
Horizontal Field of View 24°
Horizontal Display Resolution 640pixel
Vertical Detector Resolution 288pixel
Tampilkan Lebih Banyak